Grant funding, capital allowances, and compliance pathways for commercial heating upgrades in the UK – what applies to EHP® installations, amounts, and how to apply.
EHP® (Enhanced Heat Performance) nanotechnology radiators reduce commercial heating energy consumption by up to 55% by operating at a supply temperature of 30–35°C rather than the 55–80°C required by conventional central heating radiators. In the UK, that outcome qualifies EHP® installations for three distinct funding and tax mechanisms – each operating independently, each stackable with the others.
The UK is unusual among our markets in combining a direct installation grant, an uncapped tax deduction, and a compliance deadline within a single funding environment. A well-structured EHP® project can engage all three.
Grant programme
Programme type: Capital grant
Administering body: Ofgem, on behalf of the Department for Energy Security and Net Zero (DESNZ)
Programme dates: Continuous; no published end date.
Benefit: Up to £7,500 for heat pump installations.
Source: gov.uk/apply-boiler-upgrade-scheme
The Boiler Upgrade Scheme funds the replacement of fossil fuel heating systems with heat pumps. The grant is paid to the installer and passed to the building owner as a reduction in the installation cost. Heat pumps installed into conventional central heating radiator circuits running at 55–80°C cannot achieve the efficiency their specifications promise – the temperature differential required is too small to operate the heat pump at a useful coefficient of performance.
EHP® central heating radiators change this. When a heat pump is connected to a circuit of EHP® radiators operating at 30–35°C, the heat pump can achieve a coefficient of performance above 8. That is the operating condition the Boiler Upgrade Scheme was designed to incentivise – and EHP® is what makes it achievable in existing commercial buildings without replacing the entire distribution system.
How EHP® qualifies: EHP® radiators are installed as part of a heat pump system upgrade. The grant funds the heat pump; EHP® radiators are the enabling measure that makes the heat pump perform. The combined installation qualifies for the £7,500 grant. An installer accredited under the MCS (Microgeneration Certification Scheme) must carry out the installation.
How to apply: Applications are submitted by the MCS-accredited installer through Ofgem's online portal. HNordic can provide technical documentation confirming the operating temperature characteristics of EHP® radiators for inclusion in the installer's application.
Tax relief
Programme type: Capital tax relief
Administering body: HMRC
Programme dates: Continuous; no published end date.
Benefit: 100% first-year deduction on qualifying plant and machinery. AIA cap: £1 million per year. Full Expensing: uncapped for incorporated companies.
Source: gov.uk/capital-allowances
The Annual Investment Allowance and Full Expensing allow UK companies to deduct the full cost of qualifying plant and machinery from taxable profit in the year of purchase, rather than depreciating the asset over its working life. EHP® central heating radiators are qualifying plant. For a company paying 25% corporation tax, a £100,000 EHP® installation produces a £25,000 reduction in tax owed in year one.
The AIA cap of £1 million per year is sufficient to cover most standalone EHP® installations. For larger projects – or where EHP® is installed as part of a full HNordic energy stack including wind generation and battery storage – Full Expensing is uncapped and applies to the entire qualifying investment.
How EHP® qualifies: EHP® central heating radiators are plant and machinery. The allowance is claimed on the company's corporation tax return for the period in which the expenditure is incurred. No prior application or approval is required.
How to apply: Claim on the CT600 corporation tax return. Your accountant or tax adviser handles this; no interaction with HMRC is required prior to purchase. Capital allowances are not competitive and are not subject to application windows or budget limits.
Compliance obligation
Programme type: Statutory compliance obligation
Administering body: Environment Agency (England); equivalent bodies in Scotland, Wales, and Northern Ireland
Programme dates: Phase 4 audit deadline: 5 December 2027.
Source: gov.uk/guidance/energy-savings-opportunity-scheme-esos
ESOS requires large UK enterprises – broadly, those with more than 250 employees or more than £50 million annual turnover and £43 million balance sheet – to commission a comprehensive energy audit every four years. Phase 3 compliance closed in December 2026. Phase 4 audits are due by 5 December 2027.
ESOS is not a grant. It is a legal obligation with financial penalties for non-compliance. Its relevance to EHP® installations is the same as EKL in Sweden: the audit identifies heating as the dominant energy cost in most commercial buildings, documents the baseline at board level, and creates a formal, time-bounded recommendation to act. The difference in the UK is that ESOS non-compliance carries a published penalty regime, which adds a cost-of-inaction dimension that is absent from the Swedish equivalent.
An ESOS audit that identifies heating as the largest reducible cost – and recommends an upgrade to a system that reduces consumption by up to 55% – provides exactly the documented justification a CFO requires to approve capital expenditure.
How to use ESOS as a funding lever: Commission the audit early. Ensure heating is fully scoped. Use the audit output to justify the EHP® capital expenditure internally and, where applicable, as the basis for a Boiler Upgrade Scheme or capital allowances claim.
Worth knowing
The Boiler Upgrade Scheme and Full Expensing were not designed to work together. The scheme funds the heat pump installation; the allowance provides a 25% tax reduction on the remaining cost. In practice, a qualifying heat pump installation that includes EHP® radiators can combine both: the grant reduces the gross cost, and Full Expensing applies to the net cost after grant. HMRC's position is that capital allowances apply to the expenditure actually incurred by the company – so the £7,500 grant reduces the qualifying expenditure, and Full Expensing applies to the remainder. That remainder still produces a significant first-year tax reduction. The two instruments do not cancel each other. They compound. The detail is in the wording of the Capital Allowances Act 2001, section 532 – most building owners have not read it, but their accountants have or should have. Full detail and project-specific advice →
United Kingdom — project enquiry
Capital allowances, the Boiler Upgrade Scheme, and ESOS interact differently depending on building size, ownership structure, and installation scope. We can advise on what applies before you commission a grant consultant.
Get in touch